44 research outputs found

    Self-calibration of the 1 MN deadweight force standard machine at INRiM

    Get PDF
    open4noThe INRiM 1 MN deadweight force standard machine (DFSM) was installed in 1995. It adopts a binary sequence of ten weights whose combinations generate forces up to 1 MN. The advantage of this system lies in the self-calibration of its weights. The procedure is based on the comparison between two forces generated by a single weight and by a group of smaller weights, nominally equal. After 25 years, a verification of the DFSM was performed. Results are within the declared CMC limits, i.e. a relative expanded uncertainty of 2 × 10-5.openPrato, A.; Mazzoleni, F.; Facello, A.; Germak, A.Prato, A.; Mazzoleni, F.; Facello, A.; Germak, A

    Calibration of multicomponent force and moment transducers using uniaxial force standard machines integrated with tilted plates

    Get PDF
    Traceability of multicomponent force and moment transducers (MCFMTs) is a metrological priority as stated within the document of future strategy 2017-2027 of the Consultative Committee of Mass and Related Quantities of Bureau International des Poids et Mesures (BIPM). In this paper, a calibration system using force standard machines (FSMs) integrated with tilted plates is described. The main advantage of this method is the possibility to apply force and moment components using existing uniaxial FSMs without the necessity to modify them or to develop specific ones. On the other hand, force and moment components cannot be fully independently applied. Expanded uncertainties of the applied side forces and moments are in the order of around 5%, acceptable for several industrial applications. A procedure for the calibration and the uncertainty assessment of MCFMTs is also provided. Calibration results, in terms of main and cross-talk sensitivities, of a six-components transducer are shown. This method is easily implementable and can be adopted to improve the current standard

    Dynamic calibration system for seismometers: Traceability from 0.03 Hz up to 30 Hz

    Get PDF
    Mechanical calibration and traceability of seismometers in operating conditions are still a technical challenge, since very low-frequency ranges (below 0.1 Hz) are involved, and sensors under investigation are generally heavy and bulky. Recently, within the vibration metrology field, some pioneering works proposed to evaluate the seismometers’ sensitivity by applying laboratory mechanical calibration procedures, against primary or secondary standards, according to the ISO 16063 methods. By following this path, at INRIM, it has been developed a suitable system for short period horizontal and vertical ground velocity calibration of 3-axis seismometers. The calibration system allows to directly evaluate the sensitivities of the 2 axes perpendicular to the gravity field, with respect to the horizontal ground velocity (S-waves), and to derive the sensitivity of the vertical axis, parallel to the gravity field, with respect to the vertical ground velocity (P-waves), in the frequency range between 0.03 Hz and 30 Hz

    Training of Crisis Mappers and Map Production from Multi-sensor Data: Vernazza Case Study (Cinque Terre National Park, Italy)

    Get PDF
    This aim of paper is to presents the development of a multidisciplinary project carried out by the cooperation between Politecnico di Torino and ITHACA (Information Technology for Humanitarian Assistance, Cooperation and Action). The goal of the project was the training in geospatial data acquiring and processing for students attending Architecture and Engineering Courses, in order to start up a team of "volunteer mappers". Indeed, the project is aimed to document the environmental and built heritage subject to disaster; the purpose is to improve the capabilities of the actors involved in the activities connected in geospatial data collection, integration and sharing. The proposed area for testing the training activities is the Cinque Terre National Park, registered in the World Heritage List since 1997. The area was affected by flood on the 25th of October 2011. According to other international experiences, the group is expected to be active after emergencies in order to upgrade maps, using data acquired by typical geomatic methods and techniques such as terrestrial and aerial Lidar, close-range and aerial photogrammetry, topographic and GNSS instruments etc.; or by non conventional systems and instruments such us UAV, mobile mapping etc. The ultimate goal is to implement a WebGIS platform to share all the data collected with local authorities and the Civil Protectio

    Accurate coil springs axial and transverse stiffness measurements with multicomponent testing machines

    Get PDF
    Accurate characterization of coil springs, typically in terms of axial and transverse stiffness, is crucial in many applications, in particular in automotive engineering, such as suspensions, vibration reduction, seating, exhaust valves, gear engagement controls, transmission hose, fuel panels, car trunks, and engine hoods. These measurements are usually performed in spring testing machines along the vertical axis in quasi-static conditions. However, when springs are stressed along the main vertical axis, side forces, bending and torsion moments are generated, thus have to be evaluated. For this reason, a hexapod-shaped multicomponent force and moment transducer has been recently devised, realized and integrated into standard spring testing machines capable to measure the displacement along the main and transverse axes. In this way, forces, moments and displacement components generated by the springs can be measured and axial and transverse stiffness derived. In this work, two multicomponent spring testing machines with the hexapod-shaped force and moment transducer are described and measurements on different large coil springs are presented

    Analisi nel tempo di un condizionatore di segnale DMP40 e un calibratore BN100

    Get PDF
    Analisi, dei valori di taratura in un periodo di circa 10 anni, di un condizionatore di segnale DMP40 collegato al partitore induttivo BN100Analysis, of the calibration values in a period of about 10 years, of a DMP40 signal conditioner connected to the inductive divider BN10

    Training of Crisis Mappers and Map Production from Multi-sensor Data: Vernazza Case Study (Cinque Terre National Park, Italy)

    Get PDF
    This aim of paper is to presents the development of a multidisciplinary project carried out by the cooperation between Politecnico di Torino and ITHACA (Information Technology for Humanitarian Assistance, Cooperation and Action). The goal of the project was the training in geospatial data acquiring and processing for students attending Architecture and Engineering Courses, in order to start up a team of “volunteer mappers”. Indeed, the project is aimed to document the environmental and built heritage subject to disaster; the purpose is to improve the capabilities of the actors involved in the activities connected in geospatial data collection, integration and sharing. The proposed area for testing the training activities is the Cinque Terre National Park, registered in the World Heritage List since 1997. The area was affected by flood on the 25th of October 2011. According to other international experiences, the group is expected to be active after emergencies in order to upgrade maps, using data acquired by typical geomatic methods and techniques such as terrestrial and aerial Lidar, close-range and aerial photogrammetry, topographic and GNSS instruments etc.; or by non conventional systems and instruments such us UAV, mobile mapping etc. The ultimate goal is to implement a WebGIS platform to share all the data collected with local authorities and the Civil Protection

    Safety of B. abortus rough mutant strain RB51 administration in Buffalo cows

    Get PDF
    The objective of this study was to determine if B. abortus rough mutant strain RB51 is eliminated in Buffalo milk. Five milk buffaloes were inoculated with the triple of the recommended calfhood dose (3.0 – 10.2 x 1010 cfu/ml) of B. abortus RB51 strain by subcutaneous route in the right axillary region. Milk samples were taken aseptically on a daily basis for the first 30 days and weekly for the second and third months. The samples were inoculated on Brucella Medium Base (BMB) (Oxoid) and Rifampin Brucellae Medium (RBM) and incubated under 10% CO2 at 37°C for 10 days. The suspicious colonies were recultured in BMB and RBM. PCR analysis was also performed on milk samples. There were no isolations of bacteria with characteristics of Brucella from any of the milk samples collected during 90 days of the study. However Brucella RB51 DNA was detected on day 2 and 3 post vaccination in one buffalo cow and on day 21 post vaccination in another buffalo cow. It was concluded that the strain used at this dose wasn't eliminated by milk in Buffaloes inoculated during lactation, however PCR positive results underline the necessity of milk pasteurization in order to minimize food-chain exposure
    corecore